Bowbrook — Proposal — May 2026
About Us
Why Choose HARNCE
HARNCE Heating & Plumbing is a Gas Safe and OFTEC registered heating, plumbing and compliance contractor based in Lichfield, serving South Staffordshire and West Derbyshire. We work with homeowners, landlords and commercial clients — including care homes, schools and businesses — delivering reliable, compliant and customer-first engineering services. We do not subcontract. Every engineer who attends your site works directly for HARNCE and operates to the same standard on every visit.
✓Trained & Qualified Engineers
✓No Subcontractors — Ever
Credentials & Registrations
Gas Safe Registration
539217
All engineers Gas Safe registered
OFTEC Registration
703243
Oil heating — registered business
LPG
Registered
Liquefied petroleum gas works
Our Commitment to Care Home Clients
We understand that compliance in a care home environment is not a box-ticking exercise — it is a direct safeguard for vulnerable residents. Every HARNCE engineer working in a care setting is trained to the TMV3 standard, understands the regulatory framework that applies to your building, and documents every visit to a standard that will withstand CQC scrutiny. You will never need to chase us for paperwork — it arrives within 5 working days of every visit as standard.
Company Information
| HARNCE Ltd |
| Registered name | HARNCE Ltd t/a HARNCE Heating & Plumbing |
| Company number | 14415548 |
| VAT number | 436417690 |
| Address | 2 The Stables, Elmhurst Business Park, Lichfield, WS13 8EX |
| Freephone | 08000 199 350 |
| Lichfield | 01543 330 555 |
| Email | info@harnce.co.uk |
Your HARNCE Contacts
| Key Contacts |
| Managing Director | Mathew Hance — mathew@harnce.co.uk |
| Technical Director | Neil Harpur — neil@harnce.co.uk |
| Operations Director | Isla Harpur — isla@harnce.co.uk |
| General Enquiries | info@harnce.co.uk |
| Freephone | 08000 199 350 |
| All certificates | Available on request |
08000 199 350 | info@harnce.co.uk
We'll take care of it

Bowbrook — Proposal — May 2026
Why We Are Here
TMV Compliance — Why It Matters
HARNCE was engaged following a compliance inspection at Bowbrook carried out by Total Environmental Compliance Ltd in December 2024. That inspection identified 8 failures across the installed TMV units. In addition, our own site survey identified a further 6 unprotected mixer tap outlets. This proposal sets out how HARNCE will service all 222 TMV units, address the identified defects and maintain full compliance going forward.
What is a TMV and Why Does It Matter in a Care Home?
A Thermostatic Mixing Valve blends hot and cold water to deliver a safe, controlled outlet temperature — typically 39–43°C — preventing scalding at the point of use. In a care home where residents may have limited mobility, reduced sensation or cognitive impairment, a failed TMV presents a direct and serious risk of scalding injury. Annual testing and servicing is not optional — it is a legal requirement under multiple regulatory frameworks.
Regulatory Framework
The Legal Requirement
TMV servicing in a care home is governed by a layered framework of legislation, approved codes of practice and industry standards. Non-compliance exposes the operator to regulatory sanction, civil liability and CQC enforcement action.
HSE ACOP L8 — Legionella
Approved Code of Practice requiring regular inspection, testing and maintenance of all water fittings including TMVs. Non-compliance is a criminal offence.
HSG274 — Technical Guidance
HSE technical guidance supplementing L8. Part 2 covers hot and cold water systems and mandates annual TMV servicing including fail-safe testing to the TMV2/TMV3 scheme.
TMV3 Scheme — Healthcare
Sets the standard for TMVs in healthcare and care environments. Requires annual servicing, fail-safe testing, temperature verification and full documentation by a competent person.
HTM 04-01 — Safe Water in Healthcare
NHS Health Technical Memorandum covering water safety in care premises. Sets requirements for TMV installation, maintenance and record keeping in care settings.
Health & Safety at Work Act 1974
Places a duty of care on those in control of premises to protect all persons. A scalding incident from a failed or unserviced TMV would likely constitute a breach of this duty.
Care Quality Commission (CQC)
CQC assessments cover fundamental standards of safety. Water safety compliance and TMV servicing records are an active area of CQC scrutiny in care home inspections.
The Bowbrook Position Right Now
A third-party inspection has placed 8 TMV failures on record at Bowbrook. A further 6 mixer tap outlets have been identified during the HARNCE survey that currently have no TMV protection. Until these are resolved and a structured servicing programme is in place, Bowbrook's compliance position remains exposed. HARNCE's programme closes that gap completely.
08000 199 350 | info@harnce.co.uk
We'll take care of it

Bowbrook — Proposal — May 2026
Part One — Annual Programme
TMV Service — 222 Units
HARNCE offers two service levels for the annual TMV programme across all 222 units — 216 existing TMVs plus 6 newly installed units on the mixer tap outlets identified during our survey. All pricing shown is at standard pay-as-you-go rates. Contract pricing and discounts are shown in the Contract Options section.
Essential Service
Test, record and flag — compliance audit
1.Confirm asset location and verify isolation valves are present and operable✓
2.Run outlet for 60 seconds and record baseline temperature before any intervention — flag immediately if above 41°C✓
3.Verify blended temperature reaches 39–43°C within one minute of flushing✓
4.Perform fail-safe test — isolate cold supply and confirm flow stops completely✓
5.Apply service label and record baseline temperature, pass/fail result and isolation valve condition against asset register✓
6.Provide written list of all failed units to site manager on same day✓
7.Isolate hot and cold supplies fully✗
8.Remove strainer, descale and clean all components thoroughly✗
9.Remove cartridge, inspect all internal components, replace O-ring as standard✗
10.Post-service temperature verification, fail-safe retest and written remedial report✗
~15–20 mins per valve | 222 units
£7,400 ex VAT
Full Service ⭐
Strip, descale, O-ring, certify — full internal inspection
1.Confirm asset location and verify isolation valves are present and operable✓
2.Run outlet for 60 seconds and record baseline temperature — flag immediately if above 41°C✓
3.Isolate hot and cold supplies fully and confirm isolation by briefly opening outlet✓
4.Remove strainer and cartridge — lay all components on a clean tray, note condition of O-rings and seals✓
5.Descale and clean all components — soak strainer in descaling solution, clean cartridge housing and inlet ports, rinse thoroughly✓
6.Replace O-ring as standard — replace strainer or cartridge if scaled beyond cleaning, worn or damaged✓
7.Reassemble valve in correct orientation — refit strainer, cartridge and end cap, reinstall to pipework✓
8.Open cold supply first then hot — check all connections for leaks, allow system to stabilise✓
9.Run outlet for 60 seconds — record post-service temperature, verify within 2°C of baseline and within safe range, adjust or escalate if outside tolerance✓
10.Perform fail-safe test — if hot water continues to flow rather than stopping, valve must be replaced. Record all readings, parts replaced and remedial recommendations on service sheet✓
~35–40 mins per valve | 222 units
£14,800 ex VAT
08000 199 350 | info@harnce.co.uk
We'll take care of it

Bowbrook — Proposal — May 2026
Part Two — Annual Programme
Plant Room Service — All Assets
The plant room service operates to a single comprehensive standard on every annual visit. Gas Safe-regulated boilers and pressurised water heating appliances cannot be maintained to a reduced standard. All pricing is at standard pay-as-you-go rates. Contract pricing is in the Contract Options section. Pricing is subject to confirmation following a full pre-contract plant room survey.
One Standard. No Compromise.
For boilers, water heaters and associated plant, HARNCE operates one thorough service standard on every visit. This is a Gas Safe requirement, not a choice.
Boilers — 2 × Elco THISION L ECO 100
| Service Steps |
| Visual inspection of casing, flue and combustion chamber |
| Check and record gas inlet pressure |
| Inspect and clean burner assembly and heat exchanger |
| Check ignition electrodes, flame sensor and all seals |
| Inspect and clear condensate trap and pipework |
| Full combustion analysis — results recorded |
| Test all safety devices and system pressure |
| Complete Gas Safe service record and written report |
Pumps — 2 × Grundfos MAGNA3
| Service Steps |
| Check pump operation, running mode and performance data |
| Inspect for noise, vibration, leaks and electrical connections |
| Check isolation valves and flexible connections |
| Record findings and update asset register |
Expansion Vessels — 3 Units
| Service Steps |
| Isolate and check nitrogen charge pressure |
| Re-inflate to correct pressure if required |
| Inspect shell, Schrader valve and connections for corrosion |
| Reinstate and verify system pressure — record findings |
Water Heaters — 2 × Andrews ECOflo EC380
| Service Steps |
| Inspect casing, flue and all associated pipework |
| Inspect and clean burner and ignition system |
| Check anode rod condition — replace if required |
| Verify thermostat and high limit thermostat operation |
| Full combustion analysis and condensate system check |
| Record stored water temperature for Legionella compliance |
| Check pressure relief valve — complete Gas Safe record |
Pressurisation & Air Separation
| Service Steps |
| Check and record system fill pressure and settings |
| Test high/low pressure alarms and auto-fill function |
| Purge air from separator and flush collected debris |
| Inspect all hoses, connections and isolation valves |
General Plant Room — Every Visit
| Included as Standard |
| Visual inspection of all visible pipework and insulation |
| Check plant room floor for signs of leakage |
| Photograph any areas of concern |
| Written condition report with prioritised recommendations |
| Asset | Units | Est. Time | PAYG Cost |
| Elco THISION L ECO 100 boilers | 2 | ~5 hrs | £500 |
| Andrews ECOflo water heaters | 2 | ~5 hrs | £500 |
| Grundfos MAGNA3 circulation pumps | 2 | ~1.25 hrs | £125 |
| Flamco pressurisation unit | 1 | ~1 hr | £87 |
| Stourflex air & dirt separator | 1 | ~40 mins | £62 |
| Expansion vessels | 3 | ~1.25 hrs | £125 |
| General plant room inspection | — | ~1 hr | £87 |
| Total annual plant room service | — | ~15.5 hrs | £1,600 ex VAT |
08000 199 350 | info@harnce.co.uk
We'll take care of it

Bowbrook — Proposal — May 2026
Choose Your Option
Contract Options
All three options cover the same Essential and Full service levels across all 222 TMV units and the full plant room. The difference is in the discount level, the benefits included and the total saving over the term. The first annual service is invoiced on completion. Services 2 onwards are spread over 12 equal monthly payments each.
Pay As You Go
No contract — standard rate
What's Included
✗Discount on works: None — standard rate applies
✗Float stock held: None
✗TMV replacements included: None — quoted separately
✗Price certainty: None — rate card applies
✗CQC compliance letter: Not included
Service Pricing
Essential TMV (222 units)£7,400
Full TMV (222 units)£14,800
Plant room service£1,600
Essential + Plant Room£9,000
Full + Plant Room£16,400
2 Year Fixed
10% discount — 3 services total
What's Included
✓Discount on all works: 10%
✓Float stock held: 3 units on hand
✓TMV replacements included: 3 per year at no cost
✓Price certainty: Fixed for 2 years
✗CQC compliance letter: Not included
Service Pricing (10% discount applied)
Essential TMV (222 units)£6,660
Full TMV (222 units)£13,320
Plant room service£1,440
Essential + Plant Room£8,100
Full + Plant Room£14,760
3 Year Fixed ⭐
15% discount — 4 services total
What's Included
✓Discount on all works: 15%
✓Float stock held: 10 units on hand
✓TMV replacements included: 10 per year at no cost
✓Price certainty: Fixed for 3 years
✓CQC compliance letter: Included annually
Service Pricing (15% discount applied)
Essential TMV (222 units)£6,290
Full TMV (222 units)£12,580
Plant room service£1,360
Essential + Plant Room£7,650
Full + Plant Room£13,940
Services 2, 3 and 4 — Spread Over 12 Monthly Payments Each
On a 2 or 3 year fixed contract, the cost of each subsequent annual service is spread equally over the 12 months that follow, collected by GoCardless Direct Debit. This means after the first service you have a fixed, predictable monthly payment for the remainder of the contract term — no large annual invoices and no surprises.
08000 199 350 | info@harnce.co.uk
We'll take care of it

Bowbrook — Proposal — May 2026
Pricing Summary
Your Options at a Glance
Contract pricing includes the TMV replacement allowance, float stock holding and a 12.5% contingency for unforeseen time on site. The first service is invoiced on completion. Services 2 onwards are spread over 12 equal monthly payments. All prices exclude VAT.
| Option | First Service | Mths 1–12 | Mths 13–24 | Mths 25–36 | Total Saving |
| Essential TMV + Plant Room — PAYG | £9,000 | — | — | — | — |
| Essential TMV + Plant Room — 2 Year Fixed | £8,100 | £800/mth | £840/mth | — | £3,240 |
| Essential TMV + Plant Room — 3 Year Fixed | £7,650 | £756/mth | £794/mth | £834/mth | £7,614 |
| Full TMV + Plant Room — PAYG | £16,400 | — | — | — | — |
| Full TMV + Plant Room — 2 Year Fixed | £14,760 | £1,420/mth | £1,491/mth | — | £5,576 |
| ⭐ Full TMV + Plant Room — 3 Year Fixed | £13,940 | £1,346/mth | £1,413/mth | £1,484/mth | £12,348 |
£4,980Saving on scheduled services over 3 years — Full + plant room vs standard rate
£2,588Saving on reactive works over 3 years — based on 25 callouts per year at avg £250
£12,348Total estimated saving — Full + plant room, 3 year fixed vs paying standard rate
Recommended: Full Service — 3 Year Fixed
First service on completion — then fixed monthly payments for 36 months
£1,346/month
After first service of £13,940 ex VAT on completion
Our Recommendation
Bowbrook has 222 TMVs — 216 existing units with 8 failures on record, plus 6 mixer tap outlets identified during our survey requiring TMV installation. Add the plant room assets and you have a significant compliance programme that needs to be managed consistently. The Full service on a 3 year fixed contract delivers comprehensive, CQC-defensible maintenance across every asset, with up to 10 TMV replacements per year included, failed valves replaced on the same visit, an annual CQC compliance summary letter, and an estimated total saving of £12,348 compared to standard rates.
Remedial and recommended works: see Page 7
First service: £13,940 | Then £1,346/month
08000 199 350 | info@harnce.co.uk
We'll take care of it

Bowbrook — Proposal — May 2026
Additional Works
Remedial & Recommended Works
The following works have been identified during the compliance inspection and the HARNCE site survey. They are separate from the annual service programme and will be quoted and agreed individually. Contract customers receive the applicable discount on all works listed below.
Section A — TMV Remedial Works
Known Failures — 8 Units from Compliance Inspection
| Asset ID | Floor | Location | Fixture | Failure Type |
| 335559 | Ground | Room 5 Cardinal | HWB | Blending valve failed fail-safe check |
| 335615 | 1st Floor | Room 14 Iris | HWB | Blending valve failed fail-safe check |
| 335618 | 1st Floor | Room 12 Iris | Shower | Blending valve failed fail-safe check |
| 335633 | 1st Floor | Room 4 Iris | HWB | Blending valve failed fail-safe check |
| 335645 | 1st Floor | Kitchen Marigold | Sink | Blending valve failed fail-safe check |
| 335711 | 1st Floor | Room 1 Waterlily | HWB | Blending valve failed fail-safe check |
| 335641 | 1st Floor | Assisted Bathroom Iris | HWB | Faulty isolation valves — no access to isolate |
| 335692 | 1st Floor | Room 11 Waterlily | Shower | Faulty isolation valves — cannot turn off fully |
| Remedial Scope | Detail | PAYG | 2 Year (10%) | 3 Year (15%) |
| Type A — Investigation, deep clean & O-ring (6 valves) | 60 mins per valve | £630 | £567 | £536 |
| Type A — Full replacement if valve cannot be restored (6 valves) | Additional 15 mins + valve | £822 additional | £740 | £699 |
| Type B — Isolation valve replacement (2 locations) | 2.5 hrs per location | £620 | £558 | £527 |
| Best case total (Type A clean resolves + Type B) | | £1,250 | £1,125 | £1,063 |
| Worst case total (all Type A replaced + Type B) | | £2,072 | £1,865 | £1,761 |
Section B — Recommended TMV Installations
Recommended Works — Pending Authorisation
Pending Client Authorisation
ℹ
6 Mixer Taps — TMV Installation Recommended
During the HARNCE site survey, 6 mixer tap outlets were identified that currently have no TMV protection. Following discussion with site management, it is recommended that TMV2/TMV3 approved thermostatic mixing valves are installed on each of these outlets to bring them into line with the TMV3 standard and ensure consistent compliance across the site. These 6 units are included in the 222-unit annual service count from year one of the contract. These works are subject to client authorisation and have not been included in the service contract pricing above.
| Recommended Scope | Detail | PAYG | 2 Year (10%) | 3 Year (15%) |
| TMV supply and installation (per unit) | ~60–75 mins per tap — isolate, fit TMV, test and commission | £224 | £202 | £190 |
| Total for all 6 units | Subject to site access and pipework conditions | £1,344 | £1,210 | £1,142 |
Section C — Plant Room Remedial Works
Plant Room Defects — Survey Findings
⚠
Item 1 — Plant Room Floor Leak
Significant rust staining visible on the plant room floor around the dirt separator drain and low-level pipework, indicating an active or historic water leak. Requires investigation, repair or component replacement. Left unaddressed this will accelerate corrosion of adjacent plant.
⚠
Item 2 — Corroded Expansion Vessel Pipework
The pipework connection at the expansion vessel base shows significant corrosion beyond normal wear. The condition of the fittings represents a potential system integrity risk. Investigation and likely replacement of the affected section is recommended.
| Remedial Item | PAYG | 2 Year (10%) | 3 Year (15%) |
| Floor leak investigation & repair | £500–£700 | £450–£630 | £425–£595 |
| Corroded expansion vessel pipework | £500–£800 | £450–£720 | £425–£680 |
| Combined plant room remedial budget | £1,000–£1,500 | £900–£1,350 | £850–£1,275 |
08000 199 350 | info@harnce.co.uk
We'll take care of it

Bowbrook — Proposal — May 2026
Terms & Conditions
What You Need to Know
The following terms apply to all works carried out by HARNCE Heating & Plumbing at Bowbrook Care Home under this proposal and any resulting contract.
Scope of Scheduled Works
The fixed contract price covers the annual scheduled TMV and plant room service only. Any additional works identified during a service visit will be quoted and agreed in writing before proceeding, at the applicable contract discount rate.
TMV Replacement Allowance
Up to 3 or 10 like-for-like TMV replacements per year (depending on contract) are included where a valve cannot be restored during the annual service. Does not cover damage by third parties, system contamination or works by others. Replacements beyond the annual allowance charged at fixed replacement price less applicable contract discount.
Float Stock
HARNCE maintains float stock TMV units for the duration of the contract. Used units replaced within 5 working days. Float stock remains the property of HARNCE until installed.
Payment Terms
First service invoiced on completion, payable within 14 days. Contract services from service 2 onwards collected by GoCardless Direct Debit in equal monthly instalments. Remedial and recommended works invoiced on completion, payable within 14 days.
Subject to Final Survey
Plant room pricing subject to confirmation following a full pre-contract survey. TMV pricing based on the asset register dated December 2024 and subject to verification on first visit. Any material variation agreed in writing before commencement.
Recommended Works
The 6 mixer tap TMV installations are recommended works pending client authorisation. They are not included in the service contract price. Once authorised, they will be carried out at the applicable contract discount rate and the units added to the annual service register.
Access
Bowbrook is responsible for ensuring HARNCE engineers have safe, unobstructed access to all assets. Where access cannot be gained due to circumstances beyond HARNCE's control, time spent on site remains chargeable. Inaccessible assets reported to site manager on the day.
Inflation & Price Review
Fixed term contract prices held for the duration of the fixed term. A maximum CPI-linked increase of 5% may apply at the start of year 3 on 3 year contracts, with 30 days written notice.
Cancellation
Fixed term contracts may not be cancelled during the fixed term except by mutual written agreement. Early termination may be subject to a fee equivalent to the remaining contract value.
Documentation
Full updated asset register, test certificates and written service report provided within 5 working days of every visit. Gas Safe records provided for all gas appliances. CQC compliance summary letter issued annually on 3 year contracts.
Getting Started
Next Steps
| # | Action | Who |
| 1 | Select service level (Essential or Full) and contract option (PAYG / 2 Year / 3 Year) | Bowbrook |
| 2 | Sign the contract — discount applies immediately to all works including remedials | Both parties |
| 3 | Authorise recommended TMV installations on 6 mixer tap outlets if required | Bowbrook |
| 4 | HARNCE carries out all remedial and recommended works at contract discount rate | HARNCE |
| 5 | HARNCE completes full plant room survey to confirm final contract scope | HARNCE |
| 6 | First annual service completed — all 222 TMVs and full plant room | HARNCE |
| 7 | GoCardless Direct Debit established — monthly payments commence for service 2 | Both parties |
Ready to Talk?
Call us on 08000 199 350, email info@harnce.co.uk or speak to Mathew Hance directly on 07376 181780. We are happy to walk through any part of this proposal or adjust the scope to your requirements. This proposal is valid for 30 days from the date of issue. All prices exclude VAT. Company registration: 14415548. VAT: 436417690.
✉
info@harnce.co.uk
Email us
🌐
harnce.co.uk
Visit our website
HARNCE Heating & Plumbing | Gas Safe: 539217 | OFTEC: 703243 | Reg: 14415548
We'll take care of it